<ErrorMessage>
SAT: Engine Leadscrew temperature out of range
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The measured leadscrew temperature is outside the range of reasonable values.
This is likely due to a disconnected or faulty sensor. The leadscrew temperature
sensor is mounted to the leadscrew nut and is disconnected when a head is
replaced. If the cable and sensor seem fine, the LUE may be faulty.
</text></DescriptionText>
<DescriptionText><text>
Note that faulty temperature readings will result in incorrect plate geometry!
</text></DescriptionText>
<DescriptionText><text>
This error message can be temporarily disabled by with "set sat lst 0".
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and call Creo Service.
</text></DescriptionText>
</OperatorAction>
<Cause>
Faulty leadscrew temperature sensor or cable.
</Cause>
<Cause>
Faulty LUE
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:48 2008 PST
</Updated>
<Links>
</Links>
</Error>